Copper, Serum or Plasma
Test Code: 001586
Performing Lab: LabCorp
CPT Code: 82525 001
Synonym
Cu, Plasma; Cu, Serum
Specimen Type
Serum OR plasma
Specimen Container
Royal blue-top (EDTA) tube OR royal blue-top without EDTA
Volume
1 mL
Minimum Volume
0.4 mL (Note:This volume does NOT allow for repeat testing.)
Specimen Handling
Serum MUST be separated from cells within 45 minutes of collection and transferred to a certified metal-free transport tube (PeopleSoft No. 111166). Plasma may be separated immediately and transferred to a certified metal-free transfer tube (PeopleSoft No. 111166) for shipment to the laboratory.
Unacceptable Conditions
Certified metal-free plastic transport tube not submitted; unspun royal blue-top tube from which the plasma or serum has not been removed; gel-barrier tube.
Temperature
Maintain specimen at room temperature.
Methodology
Inductively-coupled plasma/mass spectrometry (ICP/MS)
Stability
Room Temperature: 28 days
Refrigerated: 28 days
Frozen: 28 days
Refrigerated: 28 days
Frozen: 28 days
TAT
2 - 4 days one working day.
| Result Code | Result Name | LOINC |
|---|---|---|
| 001586 | Copper, Serum or Plasma | 5631-7 |
Select Print Details
Select an option which you would like to print: