Insulin Autoantibodies (IAA) (Endocrine Sciences)
Test Code: 141598
|
Performing Lab: LABCORP ESOTERIX ENDOCRINOLOGY |
CPT Code:
86337
|
Specimen Container | Red-top tube or gel-barrier tube |
Specimen Type | Serum, FROZEN |
Volume | 0.5 mL |
Minimum Volume | 0.2 mL (NOTE:This volume does NOT allow for repeat testing.) |
Temperature | FREEZE |
Specimen Handling | Transfer the serum into a LabCorp PP transpak frozen purple tube with screw cap (LabCorp #49482). Freeze immediately and maintain FROZEN until tested. To avoid delays in turnaround time when requesting multiple test on frozen specimens, PLEASE SUBMIT FROZEN SPECIMENS FOR EACH TEST REQUESTED. |
Methodology | Insulin-I125 binding capacity |
Stability | Room Temperature: 2 days, Refrigerated: 3 days, Frozen: 2 years |
Unacceptable Conditions | Radioactive isotopes administered 24 hours prior to venipuncture |
Days Set-Up | M-Sat |
TAT From Set-Up | 7 - 12 Days |
Result Code | Result Name | LOINC |
141600 | Insulin Antibodies | 8072-1 |