Vitamin K1
Test Code: 121200
|
Performing Lab: LABCORP BURLINGTON |
CPT Code:
84597
|
Specimen Container | Lavender-top (EDTA) plasma tube, preferred. Also acceptable are greentop(lithium heparin)plasma tube, gel-separated (SST) serum tube, and red-top serum tube. For amber plastic transport tube and amber-top, order LabCorp N° 23598. |
Specimen Type | Serum or plasma, FROZEN and PROTECTED FROM LIGHT |
Volume | 1 mL |
Minimum Volume | 0.5 mL (Note: This volume does NOT allow for repeat testing.) |
Temperature | Specimens should be light-protected, and shipped at room temperature orrefriger ated (preferred) temperature. |
Specimen Handling | The blood is to be collected by venipuncture into a Vacutainer® blood collection tube andmix ed immediately by gentle inversion at least six times to ensure adequate mixing. Allow serum samples to clot for at least 10 minutes. Separate plasma/serum from red cells by centrifugation. PROTECT FROM LIGHT. Transfer plasma/serum specimen to labeled amber plastic transport tubewith a mber stopper and freeze. For amber plastic transport tube and amber stopper, order LabCorp Nº 23598. |
Methodology | Liquid chromatography/tandem mass spectrometry (LC/MS-MS) |
Stability | Room Temperature: 7 days, Refrigerated: 14 days, Frozen: 28 days |
Unacceptable Conditions | Receipt of mild or grossly lipemic specimen; receipt of grossly hemolyzed specimen; receipt of specimen not protected from light; receipt of specimen outside of stability; receipt of citrate plasma. |
Days Set-Up | M,W,F |
Shift Performed | 1 |
TAT From Set-Up | 4 - 6 Days |
Result Code | Result Name | LOINC |
121201 | Vitamin K1 | 9622-2 |