Select Print Details


Thyrotropin Receptor Antibody, Serum
Test Code: 010314
|
Performing Lab: LABCORP BURLINGTON |
CPT Code:
83520
|
Specimen Container | Gel-barrier tube (preferred) or red-top tube |
Specimen Type | Serum |
Volume | 1 mL |
Minimum Volume | 0.7 (NOTE: This volume does NOT allow for repeat testing) |
Temperature | Refrigerate |
Specimen Handling | If other than a gel-barrier tube is used, transfer separated serum to plastic transport tube. |
Methodology | Electrochemiluminescence Immunoassay (ECLIA) |
Stability | Room Temperature: Unstable (stability determined by manufacturer or literature reference), Refrigerated: 6 days (stability determined by manufacturer or literature reference), Frozen: 12 months (stability determined by manufacturer or literature reference) |
Unacceptable Conditions | Citrate plasma specimen; samples collected in heparin or from patients on heparin therapy: lipemic or hemolyzed serum samples; improper labeling |
Days Set-Up | M,W,F |
Shift Performed | 1 |
TAT From Set-Up | 1 - 3 Days |
Result Code | Result Name | LOINC |
010317 | Thyrotropin Receptor Ab, Serum | 5385-0 |